User Manual

5. Status LEDs, Alarms, and Troubleshooting
Page 29
Troubleshooting in case of unknown IP address or password:
If the IP address or password was inadvertently changed or forgotten so that access
to the Web GUI is not possible, a Reset button inside the unit is provided.
Note: Be aware that this button will set back all data to factory defaults.
Notice: As using the Reset button requires the unit to be in operation while open, only
suitably qualified personnel are allowed carry out the procedure described in the
following and only after becoming familiar with all safety notices, installation, operation
and maintenance procedures contained in this manual.
Danger: Electrical hazard. Danger of death or fatal injury from electrical
current. Obey all general and regional installation and safety regulations
relating to work on high voltage installations, as well as regulations covering
correct use of tools and personal protective equipment.
Use the key provided with the unit to unlock both locks at the left side of the cabinet
and unlatch them. Then, you can open the cabinet door.
Danger: Electrical hazard. Danger of death or fatal injury from electrical
current inside the unit in operation. Make sure not to touch anything but the
Reset button.
The Reset button is located on the Control Board (located in the top right corner of the
repeater):
figure 5-1 Location of Control Board
figure 5-2 Reset button on Control
Board
Press the button for 5 seconds and a restart of the Web GUI will be initiated, setting
back the settings to the factory defaults:
IP Address: 192.168.1.150 OMC Connection IP Address: 0.0.0.0
Heartbeat ON Heartbeat Interval: 30min
Thus, you can login to the Web GUI with the default password again.
Note: Do not forget to close the cabinet, latch the two locks and lock them with
the key.