User Manual
4. Commissioning
Page 26
MF0123A1A PSR 700/800 MHz
Pinning of M12 Circular Plug-12P (male)
Detail view A
Pin
Name
Color
1
NC
brown
2
NO
blue
3
CC
white
4
NC
green
5
NO
pink
6
CC
yellow
7
NC
black
8
NO
gray
9
CC
red
10
NC
violet
11
NO
red/blue
12
CC
gray/pink
Dry Contacts Alarm Information
Dry Contacts
Relay 1
Relay 2
Relay 3
Relay 4
Alarm Monitoring
Alarm Information
1,2,3
4,5,6
7,8,9
10,11,12
AC Fail Alarm
NO+CC
NC+CC
NC+CC
NC+CC
Power Failure (loss of
normal AC power supply)
DL Shutdown Alarm
NC+CC
NO+CC
NC+CC
NC+CC
System Failure
(failure of critical system
components)
UL Shutdown Alarm
NC+CC
NO+CC
NC+CC
NC+CC
PLL Lock Detector
Alarm
NC+CC
NO+CC
NC+CC
NC+CC
Isolation Alarm
NC+CC
NO+CC
NC+CC
NC+CC
DL VSWR Alarm
NC+CC
NC+CC
NO+CC
NC+CC
Antenna Failure
(malfunction of the
donor/service antennas)
UL VSWR Alarm
NC+CC
NC+CC
NO+CC
NC+CC
DL HPA Fail Alarm
NC+CC
NC+CC
NC+CC
NO+CC
PA Failure
(failure of active RF-
emitting devices
UL HPA Fail Alarm
NC+CC
NC+CC
NC+CC
NO+CC
Manual Amp Off
NC+CC
NC+CC
NC+CC
NO+CC
Alarm Status. Normal (NC+CC), Alarm (NO+CC)
Relay Contact: NC → 1,4,7,10 / NO → 2,5,8,11 / CC → 3,6,9,12
4.2.9. LAN Connection
For local access to the PSR, connect an RJ485 network cable to the NMS/GUI
connector (location see figure 4-1). Make sure that your local PC meets the