User Manual

4. Commissioning
Page 16
MF0123A1A PSR 700/800 MHz
4. Commissioning
Read and observe the health, safety, and property damage warnings as well as the
description carefully to avoid mistakes and proceed step-by-step as described.
Attention: Do not operate the PSR without terminating the antenna connectors.
The antenna connectors may be terminated by connecting them to their
respective antennas or to a dummy load.
Notice: Only qualified personnel should carry out the electrical, mechanical,
commissioning, and maintenance activities that require the unit to be powered
on when open.
When opening the PSR do not damage the warranty labels on the internal
devices. The warranty is void if the seals are broken.
Ensure that all connections have been performed according to chapter 4.2.3
Connections.
To safeguard correct operation, a device that guarantees uninterruptible power
supply (e.g. an appropriate UPS) has to be connected at the POWER connector
(see figure 4-1 Connectors of PSR 700/800 MHz).
Unless otherwise agreed to in writing by CommScope, CommScope’s general limited
product warranty (http://www.commscope.com/Resources/Warranties/) shall be the
warranty governing the PSRs, including the installation, maintenance, usage and
operation of the PSRs.
4.1. Mechanical Installation
4.1.1. Health and Safety for Mechanical Installation
1. Caution: Risk of injury by the considerable weight of the unit falling. Ensure there
is adequate manpower to handle the weight of the system.
2. Caution: Risk of serious personal injury by equipment falling due to improper
installation. The installer must verify that the supporting surface will safely support
the combined load of the electronic equipment and all attached hardware and
components. The screws and dowels (wall anchors) used should also be
appropriate for the structure of the supporting wall.
3. Caution: Explosive atmospheres. To avoid explosion or fire, do not operate this
equipment in the presence of flammable gases or fumes.
4. Caution: Lightning danger. Do not install or make adjustments to this equipment
during an electrical storm.
4.1.2. Property Damage Warnings for Mechanical Installation
1. Attention: Do not install the unit in a way or at a place where the specifications
outlined in the Environmental and Safety Specifications leaflet of the supplier are
not met. Otherwise, the lifespan and performance of the repeater may be reduced.
2. Attention: Due to power dissipation, the unit may reach a very high temperature.
Ensure sufficient airflow for ventilation.
3. Attention: The repeater must be installed in a vertical position.
4. Notice: Exceeding the specified load limits may cause the loss of warranty.