8.3.4. Environmental and Safety Specifications
Environmental
Sealing class
UL Type 4X / IP66
Storage (ETS 300 019 –2 –1, class 1.2)
Temperature
- 25° to + 70° C
Vibration (sinusoidal)
5 – 62 Hz / 0.5 mm displacement
0.2 g @ 62 – 200 Hz, 3 x 5 sweeps
Vibration (random)
0.02 m
2
/s
3
10 – 50 Hz
+12 dB / Oct. 5 – 10 Hz
-12 dB / Oct. 50 – 100 Hz
3 x 30 min
Shock
none
Humidity
+ 30° C / 93 % / 96 h
Water
none
Stationary use
Operating temperature
-25° to +50 °C *
Humidity
+32°C / 93% / 24 hours
* The ambient temperature intended for installation and operation is 25°C (77°F), but the PSR is fully
functional between -25° and +50°C.
All data is subject to change without notice.
8.4. Available Configurations and SW Feature Keys
The Feature Key IDs (listed at the end of this chapter) do not distinguish between Class
A, B and DC, AC type. A detailed list of available configurations is provided below.
Class A:
AC Configurations
ID No.
PSR 700 OR 800 MHZ 2W CLASS A AC
7831758-0001
PSR 700 AND 800 MHZ 2W CLASS A AC
7831758-0011
PSR 700 OR 800 MHZ 0.5W CLASS A AC
7831758-0012
PSR 700 AND 800 MHZ 0.5W CLASS A AC
7831758-0013
PSR 700/800 MHZ 0.5/2W LOCKED CLASS A AC
7831758-0014
DC Configurations
ID No.
PSR 700 OR 800 MHZ 2W CLASS A DC
7831758-0002
PSR 700 AND 800 MHZ 2W CLASS A DC
7831758-0021
PSR 700 OR 800 MHZ 0.5W CLASS A DC
7831758-0022
PSR 700 AND 800 MHZ 0.5W CLASS A DC
7831758-0023
PSR 700/800 MHZ 0.5/2W LOCKED CLASS A DC
7831758-0024