MF0123A1F_FCC_uc Manual for PSR 700/800 MHz
With the donor calibration, the reference level for the Donor Antenna Disconnection
(DAD) Alarm can be set. Follow the procedure described below to successfully activate
the donor antenna connection supervision.
I. Connect the donor antenna cable* without antenna to BDA
II. Press the “Donor Calibration” button on page System Operation--> VSWR Check
III. The DAD alarm will appear within 3 minutes
IV. The DAD alarm shall disappear within 3 minutes after donor antenna** is
connected
* A maximum donor antenna cable loss of 8 dB at 900 MHz (ca. 328 ft /100 m with CNT-600) is
supported. Please use a donor cable with a larger diameter or install a UL2524 certified 3rd party
device capable of supervising the antenna connection in case longer cable runs are necessary.
** An antenna with at least 7 dB RL must be used
5.7.6. 700MHz Band Overview
This page displays the current 700 MHz band setting and the Input/Output Power
Level.
If you want to check the status again, you can click the 700 MHz Band menu button or
F5 refresh key to perform the status check. Automatic gain reduction is indicated by
orange color.
5.7.7. 800MHz Band Overview
This page shows the current 800 MHz band setting and the Input/Output Power Level.
If you want to check the status again, you can click the 800 MHz Band menu button or
F5 Key to perform the status check.