User's Manual

5. Setting up the Web GUI
MF0123A1F_FCC_uc Manual for PSR 700/800 MHz
Page 53
5.7.4. Antenna Isolation Check
The progress is displayed:
When the Isolation Check
is completed, the Isolation
value and Maximum Gain
are displayed (maximum
gain is calculated with
Isolation minus 20 dB):
Maximum Gain: 90 (Green color), Maximum Gain : 89~ 60 dB (Orange color),
Maximum Gain: < 60dB (Red color) Isolation Fail
5.7.5. VSWR Check and Donor Calibration
If the Return loss value is less than the Threshold value, the VSWR Fail Alarm is
generated. The shading will change from green to red in case of an alarm.
The threshold (RL Threshold) under which an alarm will be generated can be set in the
General RF Setting (see chapter 5.6.8).
Click the TEST button to start the Antenna Isolation Check.
Click the Refresh button to display the current VSWR Ratio.
Click the Donor Calibration button to start the calibration.