User's Manual
Table Of Contents
- 1. GENERAL
- 2. INTRODUCTION
- 3. COMMISSIONING
- 3.1. MECHANICAL INSTALLATION
- 3.2. ELECTRICAL INSTALLATION
- 3.3. CONNECTION OF THE ANTENNA CABLES
- 3.4. POWER CONNECTION
- 3.5. OPTICAL-FIBER-CABLE CONNECTION - RULES
- 3.6. COMMISSIONING
- 3.7. BITE AND ALARMS
- 3.8. HANDLING OF ALARMS
- 3.9. ALARM STATUS
- 3.10. STATUS LED ALARMS
- 3.11. EXTERNAL ALARM INPUTS AND OUTPUTS
- 3.12. TROUBLESHOOTING
- 4. MAINTENANCE
- 5. APPENDIX
- 6. INDEX
- LIST OF CHANGES
For plug assembly, observe the following instruction:
1. Pass one or two contacts through the
backshell and the clamp ring.
2. Place the contact(s) on the lower insulation body by pushing the groove of the
contact into the cavity. If there is only one contact, cavity A must be used. *
3. Then, mount the upper insulation body on the lower insulation body. **
4. Bring the insulator into the plug. The narrow groove of the insulator must be fitted
into the stamp of the plug.
Page 27 MF0143AUB.doc
* To release the contact for disassembling, push the inner snap to the side and pull the contact out.
** To release upper and lower insulation bodies for disassembling, use a small screwdriver and
carefully open the snap-connections at the left and the right side of the insulator without
damaging them.
5. Fasten the insulator by screwing the
backshell tight onto it. Use a spanner
with opening 32 to screw the
backshell tight (no gap).
6. Place the appropriate seal parts (with
one groove for one contact or two
grooves for two contacts) over the
cable(s) and push them into the
backshell.
Seals with
one groove
No gap
Cavity B
Upper insulation body
Cavity A