User's Manual

7 Appendix
Page 47 MF0145AQA.doc
7.2. SPECIFICATIONS
7.2.1. Electrical Specifications
Electrical
Power supply
Mains power
85 Vac to 264 Vac
110 Vac or 240 Vac
Power consumption
max. temp., fully
loaded
770 watts
room temp., idle 400 watts
Optical Link
Optical link connectors E2000/APC 8°
Optical return loss 45 dB
Fibre type Single mode E9/125 µm
Optical link budget 0 dB to 10 dB
7.2.2. Mechanical Specifications
Height, width, depth * 831 x 156 x 147 mm (32.7 x 6.1 x 5.8 in)
Weight, 22 kg (48 Ib)
* Spacing required 40 mm (1.58 in) around unit
All data is subject to change without notice.
7.2.3. Environmental and Safety Specifications
Note: For detailed information, please refer to the Environmental and
Safety Specifications leaflet of the supplier, related to ETS 300 019
(European Telecommunication Standard).
Operating temperature range -33° C to +50° C
Ingress protection
RF part IP67
Fan part IP55
All data is subject to change without notice.