User's Manual

7. Appendix
MF0150A3A.doc Manual for ION-M7P/17EHP Page 43
7.2. Specifications
7.2.1. SW Requirements
Minimum SW requirements for basic support: ION-M SW V7.0.1
7.2.2. Electrical Specifications
Electrical
Power
supply
Mains power
nominal 100 Vac to 240 Vac
operating 85 Vac or 264 Vac
Power consumption
max. temp., fully loaded 770 watts
room temp., idle 400 watts
Optical Link
Optical link connectors E2000/APC
Optical return loss 45 dB min.
Fibre type Single mode E9/125 µm
Optical link budget 0 dB to 10 dB
7.2.3. Mechanical Specifications
Height, width, depth * 831 x 156 x 147 mm (32.7 x 6.1 x 5.8 in)
Weight, 22 kg (48 Ib)
* Spacing required 40 mm (1.58 in) around unit
All data is subject to change without notice.
7.2.4. Environmental and Safety Specifications
Note: For detailed information, please refer to the Environmental and Safety
Specifications leaflet of the supplier, related to ETS 300 019 (European
Telecommunication Standard).
Operating temperature range -33° C to +50° C
Ingress protection
RF part IP67
Fan part IP55
All data is subject to change without notice.