User's Manual
3. Commissioning
MF0145ASA.docx User’s Manual for ION
®
-M7HP/85HP EU Page 29
5. Retain the cable connector with the
counter wrench and fasten the
coupling nut with the torque wrench
until the torque is applied (torque
wrench clicks).
For angled antenna connectors use your
hand to retain the cable connector and
fasten the coupling nut with the torque
wrench. Make sure only the coupling nut
is turned, not the cable connector.
3.2.8. Power Connection
Before connecting electrical power to the RU, the system must be grounded as
described in the previous section.
Depending on the RU version (AC or DC type) proceed accordingly:
3.2.8.1. AC Power Connection
Mains power must be connected at the
mains connector of the unit (see figure
3-9).
The power supply plug is part of the
delivery. The correct wiring of the power
supply plug is as follows:
figure 3-12 Mains connector
Note: For the AC power supply connection, a minimum cross section of 1.5 mm
2
is required. Each wire must observe the applicable national regulations
regarding loop impedance, voltage drop, and methods of installation.
Make sure to connect the correct voltage to the unit.
Note: Do not connect or disconnect the power cord at the mains connector while
power is on. Turn off mains power * before connecting the power cord at
the unit, then, engage mains again.
* Mains power must be interruptible with an external mains breaker. For the mains breaker,
observe the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed,
i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 13 to 16 Amps for
240-Volt service. Always make sure that your local requirements are kept.
PIN 3 -
n.c.
PIN 4 - PE
PIN 1
- L
PIN 2 - N
Torque wrench
Counter
wrench