Installation Manual

6. Notice: A spacing of 40 mm (1.58 inch) around the unit is required.
7. Notice: To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid
openings (one for the air inlet and the other for the air outlet) must be provided. Do not
block these air inlets and outlets when mounting the unit. The size of each opening must
equal at least 18 x 18 cm (>300 cm
2
). Make sure, too, there is no thermal short circuit
between the air inlet and air outlet.
8. Notice: Depending on the installation type (wall or pole), the corresponding mounting kits
must be ordered from the manufacturer. If any different or additional mounting material is
used, ensure that the mounting remains as safe as the mounting designed by the
manufacturer. The specifications for stationary use of the unit must not be exceeded.
Ensure that the static and dynamic strengths are adequate for the environmental
conditions of the site. The mounting itself must not vibrate, swing or move in any way that
might cause damage to the unit.
9. Notice: To avoid damage when mounting the unit, always make sure that the M8 washers
(DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front of the
mounting drillings of the unit.
Specified torques have to be observed for certain mounting procedures according to the following table:
Type
Lens head
screws
Hex
nuts
Spacing
bolts
PG
(plastic)
PG (alu-
minum)
Thread
M 4 M 8 M 4 M 8 PG 13.5 PG 29
Specified torques
3.3 N-m 27 N-m 2.3 N-m 27 N-m 3.75 N-m 10 N-m
table Fehler! Kein Text mit angegebener Formatvorlage im Dokument.-1 Specified torques
Note: To avoid damage when mounting the unit, always make sure that the M8 washers
(DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front of the
mounting drillings of the unit.
The mounting procedures for a stand-alone unit without optional accessories are described and
illustrated in the following sections. For further information regarding special mounting procedures
including mounting of accessory equipment, please see separate manual.