User's Manual

Parameter Value
Label / Name
MAINS 1
MAINS 2
Connector type
CONINVERS M 17 series P20
4(3+PE) PINs male
PIN
1
2
3
4
L – Line conductor / Phase 1 (brown cable)
N – Neutral conductor (blue cable)
not connected (n.c.)
PE – Protection Earth (green / yellow cable)
For the AC power supply connection, a minimum cross section of 1.5
mm
2
is required. Each wire must observe the applicable national
regulations regarding loop impedance, voltage drop, and methods of
installation. Make sure to connect the correct voltage to the unit.
Note: Do not connect or disconnect the power cord at the mains connector
while power is on. Turn off mains power* before connecting the
power cord at the remote unit, then, engage mains again.
* Mains power must be interruptible with an external mains breaker. For the mains breaker,
observe the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed,
i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 16 Amps for 240-
Volt service.
3.2.6. Connection of Optical-Fibre-Cable - Rules
Optical signals are transmitted by use of optical fibres. When connecting these fibres
observe the following instructions.
Note: Care should be taken when connecting and disconnecting fibre-
optic cables. Scratches and dust significantly affect system
performance and may permanently damage the connector. Always
use protective caps on fibre-optic connectors not in use.
In general, optical fibres do not need special protective measures. However,
protection against environmental influences e.g. rodents and humidity must be
considered.
The optical fibre is a single mode fibre. Type is E9/125 µm with the following
minimum requirements: