Product Specs

SPECIFICATIONS
PCS1900
Frequency range, MHz
................Uplink ..............1850 to 1915
................Downlink ............1930 to 1995
RF output power per carrier, dBm***
Number of Carriers 1 2 4 8
GSM 43 40 37 34
CDMA 42.5 39.5 36.5 33.5
LTE 43 40* 37 34
UMTS 42.5 39.5 36.5 33.5
DL output tolerance over frequency, dB ........±1.1
DL output tolerance over temperature, dB .......±0.5
Spectrum emission mask .. . . . . . . . . . . . . . . . . . <-13 dBm / 1 MHz
Input ICP3, dBm**
................ICP3 optimized..........-12 min.
................Noise figure optimized......-18 min.
Noise figure, dB**
................ICP3 optimized..........+11 max.
................Noise figure optimized......+6 max.
..................................4.5
System Supervision and Control
Commands .................................RF on/off
..................................4 external control ports
Alarms ..................................Summary
..................................Power Supply
..................................Optical UL and DL
..........................................failure
..................................RF UL and DL failure
..................................Temperature
..................................4 external alarm inputs
Supervision .................................Composite output
..........................................power
ION-M7P/17EP/19P - Product Specification
Mechanical****
Height, width, depth, mm (in)................824 x 176 x 220
..........................................(32.4 x 6.9 x 8.7)
Weight, kg (Ib) .............................27 (59.4)
Environmental
Operating temperature range, °C.............-33 to +50
Ingress protection
RF part ............IP67
Fan part ...........IP55
Minimum SW Requirements for Basic Support
ION-M SW V7.0.1
Ordering Information
ION-M7P/17EP/19P . . . . . ..................7714179*****
Depending on the selected options and the configuration the ordering material number
contains an identifying suffix.
Extension Unit Options
No connection to extension unit possible.
Corresponding Master Unit OTRx
OTRx 70-85/90/17-21 MU-G ..............7604304-XX
* 2 dB reduction of Pout @ carrier bandwidth < 5 MHz
** from Reference point B to A
*** PAR 7.5 dB @ 0.1 %
**** Spacing required 50 mm (1.97 in) around unit
***** Subpopulations possible
All figures are typical values, unless otherwise stated.