- 3.2. ELECTRICAL INSTALLATION
- 3.3. CONNECTION OF THE ANTENNA CABLES
- 3.4. POWER CONNECTION
- 3.5. OPTICAL-FIBER-CABLE CONNECTION - RULES
- 3.6. COMMISSIONING
- 3.7. BITE AND ALARMS
- 3.8. HANDLING OF ALARMS
- 3.9. ALARM STATUS
- 3.10. STATUS LED ALARMS
- 3.11. EXTERNAL ALARM INPUTS AND OUTPUTS
- 3.12. TROUBLESHOOTING
- 4. MAINTENANCE
- 5. APPENDIX
- 6. INDEX
- LIST OF CHANGES
7. Bring the plastic ring over the cable(s), push it into the backshell and compress
the seals and plastic ring by screwing the clamp ring tight (no gap) using a
spanner with opening 20. ***
8. Connect the plug to the optical-fiber
connector of the Remote Unit, again
by fitting a stamp on the plug into the
groove of the connector.
9. To lock the connector, push the black
locking ring forward.****
Screw tight until gap is closed
Page 28 MF0143AUB.doc
*** For disassembling, release the clamping ring and remove the seals and the plastic ring first.
**** Locking mechanism: The system of locking the plug is based on a “push-pull” mechanism. The
locking ring has to be pushed forward to lock the connector and pulled back to free the
connection.
3.5.2. Protective-Tube Kit
As additional protection for the optical fibers, this connector type can be
supplemented by a special tube kit. To fasten the tube correctly, first unscrew the
clamp ring (if already installed) of the original plug kit.
Then, proceed according to the following instruction:
Groove
Push forward to lock, pull
back to free connection