User’s Manual for Remote Unit
ION-M17P/17P/17P
Page 46 M0132AKA_FCC.doc
6.3 CLEANING THE HEAT SINK
) Note: Read the health and safety warnings in chapter 1.2 Health and
Safety Warnings as well as the instructions in chapter 6.1 General
before starting with the replacement procedure. Then, proceed as
follows:
1. Switch off the remote unit. Make sure that mains is disconnected for the following
procedure.
3. Use compressed air (max. 5 bar) to
blow out the heat sink from back to
front:
2. Remove the fan plate with the fan unit
from the remote unit as described in
chapter 6.2 Replacing the Fan Unit,
steps 1 and 2:
4. In case the dirt cannot be blown out
completely and parts of it stick to the
ribs of the heat sink, clean the parts
concerned carefully from the front
using e.g. a brush. Take care that the
material is not scratched or damaged.
5. After cleaning the heat sink, mount the fan unit again according to chapter 6.2
Replacing the Fan Unit, step 6. Then, switch the remote unit back on.
Compressed air
(5
ba
r m
a
x.
)
Brush (not metallic)