Installation Instruction

Installation Instruction
The Remote Unit, Extension Unit or Master Unit has to be
mounted by proffessionel / special trained installer.
1.1. MECHANICAL INSTALLATION
1.1.1. General
Read the health and safety warnings in chapter 1.3 Health and Safety Warnings.
1. Do not install the unit in a way or at a place where the specifications outlined in the
Environmental and Safety Specifications leaflet of the manufacturer are not met.
2. It is strongly recommended to install the unit vertically. If a different installation of the remote
unit is required, please contact customer service for further information.
3. It is recommended only to use the mounting hardware delivered by the manufacturer. If
different mounting hardware is used, the specifications for stationary use of the remote unit
must not be exceeded.
Note: Exceeding the specified load limits may cause the loss of warranty!
4. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure
there is adequate manpower to handle the weight of the system.
5. Due to power dissipation, the remote unit may reach a very high temperature. Ensure
sufficient airflow for ventilation. Above and below the unit a minimum distance of 300 mm to
ceiling, floor, etc. has to be kept. Also observe the instructions in the individual mounting
procedures.
6. For outdoor installations, the pre-mounted front cover must be installed.
7. For indoor installations where the ambient temperature can reach above 40°C, the cover has
to be removed.
8. When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can
penetrate into the unit through these cables.
If any different or additional mounting material is used, ensure that the mounting remains as safe as the
mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for
the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any
way that might cause damage to the remote unit.