User's Manual

User’s Manual for
ION-M4/8 19"
Page 28 M0132AVA_FCC.doc
4.2.3. Power Connection and Grounding
figure 4-3 Mains connector and grounding
screw
Before connecting electrical power to
the units, the system must be
grounded at the grounding screw at
the front side. Unscrew the grounding
screw located at the front side (see
illustrations above) and fasten a 4
mm
2
grounding cable there.
For power supply of the ION-M4/8
19", connect mains at the mains
connector located at the front side of
the ION-M4/8 19" cabinet. If the unit is
equipped with two power supplies,
two terminals are provided, one for
each power supply.
Mains
connector
Grounding
bolts