User's Manual
4 Commissioning
Page 25
4. COMMISSIONING
4.1. MECHANICAL INSTALLATION – GENERAL
Read the health and safety warnings in chapter 1.2 Health and Safety Warnings.
1. Do not install the unit in a way or at a place where the specifications
outlined in the Environmental and Safety Specifications leaflet of the
manufacturer are not met.
2. The unit is designated for 19" rack mounting only.
3. It is recommended only to use the mounting hardware delivered by the
manufacturer. If different mounting hardware is used, the specifications for
stationary use of the remote unit must not be exceeded.
) Note: Exceeding the specified load limits may cause the loss of warranty!
4. The unit is considerably heavy. Ensure there is adequate manpower to
handle the weight of the system (43 kg).
5. Due to high power dissipation the ION-M4/8 19" can reach very high
temperatures. For that reason sufficient airflow must be ensured so that the
outside temperature and the air temperature inside the cabinet on
installation site must not exceed 40 °C. The surface temperature must not
exceed +70 C in any operating condition. Above and below the unit a
minimum distance of 1 HU to other equipment has to be kept. Also observe
the instructions in the individual mounting procedures.
6. Only operate the unit in the 19" rack with door or use additional fan module.
7. For mounting of the unit in a 19" rack, slide rails are required due to the
considerable weight of the unit.
If any different or additional mounting material is used, ensure that the mounting
remains as safe as the mounting designed by the manufacturer. Ensure that the
static and dynamic strengths are adequate for the environmental conditions of the
site. The mounting itself must not vibrate, swing or move in any way that might cause
damage to the remote unit.