7.2. SPECIFICATIONS
7.2.1. Electrical Specifications
ION-M17P/17P/17P
Electrical
Mains power 85 to 264 Vac
Power supply
Power consumption 770 watts
Optical
Connectors E2000/APC 8°
Optical return loss 45 dB minimum
Fiber type Single mode E9/125 µm
Optical link budget 0 to 10 dB
+3 dBm nominal Composite input power 2100 MHz
@ Conversion module master side
+10 dBm max
1)
-19 dBm min
2)
Interface
BTS side 1700/2100 MHz 4 connectors
System optimized for BTS power 33 dBm
43 dBm
0 dBm
Connector 3 x N Female
Antenna port
Output power See band specification
Return loss 15 dB
1700/ 2100 MHz (AWS)
Uplink 1710 to 1755 MHz Frequency range
Downlink 2110 to 2155 MHz
1 carrier +43 dBm
2 carriers +40 dBm
4 carriers +37 dBm
Output power per carrier
3)
CDMA2000
8 carriers +34 dBm
Spurious emission <-13 dBm / 1 MHz
DL output tolerance over frequency ±1.5 dB
DL output tolerance over temperature ±0.5 dB
ICP3 optimized NF optimized
UL Input ICP3 -15 dBm -18 dBm
UL noise figure
4)
7.5 dB 5.0 dB
Nominal gain Additional gain Additional Attenuation
ICP3 optimized
40 dB 0 - 22 dB 0 - 7 dB
Gain DL
NF optimized
40 dB 0 - 22 dB 0 - 7 dB
ICP3 optimized
40 dB --- 0 - 30 dB
Gain UL
NF optimized
44 dB --- 0 - 30 dB
1)
can be compensated by additional attenuation (0 - 7 dB)
2)
can be compensated by additional gain (0 - 22 dB)
3)
PAR 7.5 dB @ 0.1%
4)
Note: The noise figure (NF) stated above refers to one Remote Unit (RU) per sector. The
NF system increases with the number of the RUs per sector. It is recommended not
to operate above four RUs per sector. With four RUs per sector, the system NF will
be increased by 6 dB.