ION™-M7P/8P S (Q cabinet) Optical Remote Unit User's Manual MF0132APA
User’s Manual for ION-M7P/8P S © Copyright 2010 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice.
TABLE OF CONTENTS 1. GENERAL 7 1.1. USED ABBREVIATIONS 7 1.2. HEALTH AND SAFETY WARNINGS 9 1.3. ABOUT ANDREW SOLUTIONS 1.4. INTERNATIONAL CONTACT ADDRESSES FOR WIG CUSTOMER SUPPORT 12 11 2. INTRODUCTION 15 2.1. PURPOSE 15 2.2. THE ION-M7P/8P S (INTELLIGENT OPTICAL NETWORK; MMR) 15 3. FUNCTIONAL DESCRIPTION 17 3.1. GENERAL 17 3.2. COMPONENTS OF THE ION-M7P/8P S REMOTE UNIT 18 3.3. OPTIONAL EQUIPMENT - RELAY ALARM CONNECTING BOARD 18 4. COMMISSIONING 19 4.1. 4.1.1. 4.1.2.
User’s Manual for ION-M7P/8P S 5. ALARMS 33 5.1. BITE AND ALARMS 33 5.2. HANDLING OF ALARMS 33 5.3. ALARM STATUS 33 5.4. STATUS LED ALARMS 33 5.5. 5.5.1. 5.5.2. RELAY ALARM CONNECTING BOARD External-Alarm Inputs and Outputs Layout and Connector Description 35 35 36 5.6. REDUNDANCY RELAY CONFIGURATION 37 5.7. TROUBLESHOOTING 38 6. MAINTENANCE 39 6.1. GENERAL 39 6.2. OPENING AND CLOSING OF THE CABINET 40 6.3. REPLACEMENT OF POWER SUPPLY 41 6.4.
FIGURES AND TABLES figure 3-1 Configuration of an ION-M7P/ 8P S.......................................................... 17 figure 3-2 ION-M7P/8P S, lid .................................................................................... 18 figure 3-3 ION-M7P/8P S, base ................................................................................ 18 figure 4-1 Wall mounting........................................................................................... 20 figure 4-2 Pole mounting ............
User’s Manual for ION-M7P/8P S For your notes: Page 6 MF0132APA.
1 General 1. GENERAL 1.1.
User’s Manual for ION-M7P/8P S SISO SPD SRMU TCH TDD TDMA TX UL UMR UMTS UPS VSWR WDM WIG WiMAX Page 8 Single Input Single Output Switching Point Detector Subrack Master Unit = OTRx (Optical Transceiver) Traffic Channel Time-Division Duplex Time Division Multiple Access Transmitter Uplink Universal Measurement Receiver Universal Mobile Telecommunication System Uninterruptible Power Supply Voltage Standing Wave Ratio Wavelength Division Multiplex Wireless Innovations Group Worldwide Interoperability for Mi
1 General 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all the warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3.
User’s Manual for ION-M7P/8P S 12. ESD precautions must be observed! Before commencing maintenance work, use the available grounding system to connect ESD protection measures. 13. This unit complies with European standard EN60950. 14. Make sure the system settings are according to the intended use (see also product information of manufacturer) and regulatory requirements are met. 15.
1 General 1.3. ABOUT ANDREW SOLUTIONS Andrew Wireless Systems GmbH based in Buchdorf/ Germany, is a leading manufacturer of coverage equipment for mobile radio networks, specializing in low cost, high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage for every application: outdoor use, indoor installations, tunnels, subways and many more. Andrew Wireless Systems GmbH belongs to the Wireless Innovations Group (WIG).
User’s Manual for ION-M7P/8P S 1.4. INTERNATIONAL SUPPORT CONTACT ADDRESSES FOR WIG CUSTOMER Wireless Innovations Group (WIG) Americas: Canada United States Andrew Solutions Canada Andrew Solutions, Andrew LLC, A CommScope Company Mail 620 North Greenfield Parkway Garner, NC 27529 U.S.A. Mail 620 North Greenfield Parkway Garner, NC 27529 U.S.A. Phone +1-905-878-3457 (Office) +1 416-721-5058 (Mobile) Phone +1-888-297-6433 Fax +1-905-878-3297 Fax +1-919-329-8950 E-mail Peter.
1 General Europe: United Kingdom France Andrew Solutions UK Ltd Andrew Solutions France Mail Unit 15, Ilex House Mulberry Business Park Fishponds Road Wokingham Berkshire RG41 2GY England Mail 28, Rue Fresnel Z.A Pariwest BP 182 78313 Coignières Cedex France Phone +44-1189-366-792 Phone +33 1 30 05 45 50 Fax +44-1189-366-773 Fax +33 1 34 61 13 74 E-mail WIsupport.uk@andrew.com E-mail WIsupport@andrew.
User’s Manual for ION-M7P/8P S For your notes: Page 14 MF0132APA.
2 Introduction 2. INTRODUCTION 2.1. PURPOSE Cellular telephone systems transmit signals in two directions between a base transceiver station (BTS) and mobile stations (MS) within the signal coverage area. If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, extension of the transmission range can be achieved by means of an optical distribution system.
User’s Manual for ION-M7P/8P S The ION is easily set-up and supervised via a graphical user interface (GUI). Remote units can be commissioned through the use of built-in test equipment. An auto leveling function compensates for the optical link loss making installation easy and quick. The entire system may be monitored remotely via an Andrew OMC. This is a comprehensive management platform with SNMP protocol and X.733 standard implemented.
3 Functional Description 3. FUNCTIONAL DESCRIPTION 3.1. GENERAL The following figure shows the configuration of an ION-M7P/8P S: Crossband Coupler (CC) Part of output CC Power Amplifier 1 I²C Crossband Coupler (CC) Drawer Module +28 VDC Drawer Power Amplifier 1 ANT DL I²C Optical Module Drawer Module +28 VDC Drawer +28 VDC ANT UL UL LNA Drawer Module I²C WDM UL/DL OTRX DL o UL o e from / to Master Unit e Control Unit C161 core module Ext. Al in Ext. Al out +28 VDC Alarmboard w.
User’s Manual for ION-M7P/8P S 3.2. COMPONENTS OF THE ION-M7P/8P S REMOTE UNIT The actual configuration of the remote unit can be seen at the configuration list which is part of the delivery. The following figure shows an exemplary view of an ION-M7P/8P S remote unit to illustrate the individual components. Power supply Control unit Optical interface Final amplifiers Relay alarm connecting board Crossband coupler RF relay figure 3-2 ION-M7P/8P S, lid 3.3.
4 Commissioning 4. COMMISSIONING 4.1. MECHANICAL INSTALLATION 4.1.1. General Read the health and safety warnings in chapter 1.2 Health and Safety Warnings. 1. Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the manufacturer are not met. 2. It is strongly recommended to install the unit vertically. If a different installation of the remote unit is required, please contact customer service for further information. 3.
User’s Manual for ION-M7P/8P S 4.1.2. Wall and Pole Mounting Wall and pole mounting equipment for the unit is available. For the according mounting please refer to the mounting plan (drawing) that is part of the delivery. V1628M0 figure 4-1 Wall mounting Page 20 V1628M1 figure 4-2 Pole mounting MF0132APA.
4 Commissioning 4.2. ELECTRICAL INSTALLATION 4.2.1. General Read the health and safety warnings in chapter 1.2 Health and Safety Warnings. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property damage can be the result if the instructions contained in this manual are not followed. 2. It is compulsory to ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3.
User’s Manual for ION-M7P/8P S 4.2.2. Connections AUX connector Status LED BBU connector Mains connector Connector to Substitute Unit N-antenna connectors Optical connector Connectors to Redundant RU Connectors to main unit figure 4-3 ION-M7P/8P S, connector flange, exemplary 4.2.3. Grounding Grounding must be carried out. Connect an earth-bonding cable to the grounding connection provided at the outside of the remote unit (see chapter 4.2.2 Connections).
4 Commissioning After loosening the hex nut, connect the earth-bonding cable between the two washers as illustrated in the figure above. Then, fasten all parts again with the hex nut. The PE cables must have a minimum cross section of 16mm2. 4.2.4. Power Connection Before connecting electrical power to the units, the system must be grounded as described in the previous chapter. Mains power must be connected at the mains connector of the unit (see chapter 4.2.2 Connections).
User’s Manual for ION-M7P/8P S ) Note: Do not connect or disconnect the power cord at the mains connector while power is on. Turn off mains * power before connecting the power cord at the remote unit, then, engage mains again. * Mains power must be interrupted with an external mains breaker. For the mains breaker, observe the following recommendation: 120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the external AC breaker should be 20 Amps max.
4 Commissioning 4.5. OPTICAL-FIBRE-CABLE CONNECTION - RULES Optical signals are transmitted by use of optical fibres. When connecting these fibres observe the following instructions. ) Note: Care should be taken when connecting and disconnecting fibre-optic cables. Scratches and dust significantly affect system performance and may permanently damage the connector. Always use protective caps on fibre-optic connectors not in use. In general, optical fibres do not need special protective measures.
User’s Manual for ION-M7P/8P S ¾ Remove fibre-optic protective caps. ¾ Do not bend the fibre-optic cable in a tight radius (< 4 cm) as this may cause cable damage and interrupt transmission. ¾ Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of the fibre-optic cable that will be inserted in the optical connectors on the donor interface box. ¾ Blow out the laser receptacle with clean and dry compressed air to remove any particulate matter.
4 Commissioning For plug assembly, observe the following instruction: 1. Pass one or two contacts through the backshell and the clamp ring. 2. Place the contact(s) on the lower insulation body by pushing the groove of the contact into the cavity. If there is only one contact, cavity A must be used. * 3. Then, mount the upper insulation body on the lower insulation body. ** Upper insulation body Cavity B Cavity A 4. Bring the insulator into the plug.
User’s Manual for ION-M7P/8P S 7. Bring the plastic ring over the cable(s), push it into the backshell and compress the seals and plastic ring by screwing the clamp ring tight (no gap) using a spanner with opening 20. *** Screw tight until gap is closed 8. Connect the plug to the optical-fibre 9. To lock the connector, push the black connector of the remote unit, again by locking ring forward.**** fitting a stamp on the plug into the groove of the connector.
4 Commissioning prot ect ive plug f ibre cable plast ic ring reducer Screw t he reducer t o t he prot ect ive plug backshell wit hout gap. coupling Place t he appropriat e seal part s (wit h) one groove f or one cont act or t wo grooves f or t wo cont act s) over t he cable(s) and push t hem int o t he backshell. prot ect ive t ube Push the fibre-optic cable carefully through the tube until it comes out at the other end.
User’s Manual for ION-M7P/8P S 4.6. COMMISSIONING Read the health and safety warnings in chapter 1.2 Health and Safety Warnings as well as the description carefully to avoid mistakes and proceed step by step as described! Do not operate the remote unit without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load.
4 Commissioning Commissioning an ION-M Remote Unit Manual for Remote Unit Philips screwdriver Mounting kit Spanner, size 13 mm Drilling machine Dowels Screw driver Screw driver Spanner, size 13 mm Start Preperation Unpack RU, RU accessories and mounting kit. Mechanical installation Fasten wall or pole mounting kit to wall or pole. Mechanical installation Mount RU to mounting kit, ensure suffient air flow and avoid thermal short circuits.
User’s Manual for ION-M7P/8P S LED on? No Check power switch inside RU (RUs with door). Check mains cabling. Check mains power. Yes LED status Red Internal Error Change power supply (RUs with a door). Reduce environmental temperature. Eliminate thermal short circuit. Disconnect and connect mains. Fans should run. If not, replace the fans at RU. MU: Change amplifier setting at MU controller Orange Yellow Yes LED status Red Green Spare RU available? External error Close the door (RUs with a door).
5 Alarms 5. ALARMS 5.1. BITE AND ALARMS The Built-In Test concept comprises the monitoring of the power supplies, the power amplifiers and the optical interface. All occurring alarms can be checked via software at the master unit. 5.2. HANDLING OF ALARMS As soon as the software acknowledges a valid alarm, a message is transmitted to the master unit. If the reason for the alarm has been cleared or if the alarm should continue, a new alarm message will not be repeated.
User’s Manual for ION-M7P/8P S Status LED indication Alarms Possible on-site measures Alarms directly related to RU: Change power supply (RUs with door). Power 28 V Replace the affected remote unit. Reduce environmental temperature. Temperature Eliminate thermal short circuit. Disconnect and connect mains. Fans Red Fan * should run. If not, replace the fans at RU. I²C Disconnect and connect mains. Optical alarm Tx Amplifier “Power (MU: Change amplifier setting at MU Down” controller).
5 Alarms 5.5. RELAY ALARM CONNECTING BOARD 5.5.1. External-Alarm Inputs and Outputs There are four alarm inputs and four alarm outputs. The alarm outputs are potentialfree relay contacts. They can be used to monitor alarms with an external-alarm indicator. Each alarm output can be set individually to any alarm at the remote unit. For details please refer to the according chapter in the software manual of the master unit.
User’s Manual for ION-M7P/8P S 5.5.2. Layout and Connector Description +28 V Ext. Alarm Inputs GND 2 3 2 1 1 RF Relay for redundancy switchover Alarm Outputs figure 5-2 Relay alarm connecting board, description of connectors Connector Ext. Alarm INPUTS * 1 * PIN 1 2 3 4 Description Ext. Alarm 1 Common Ext. Alarm 2 Common Ext. Alarm 3 Common Ext. Alarm 4 Common Voltage: 0 - 5 V; Current: max.
5 Alarms Clamp 2 The alarm outputs are potential-free. They can be used to monitor alarms with an external alarm indicator. Devices connected to these outputs must not exceed a maximum switching power of 28 Vdc, 0.5 A. For the location of the connecting clamps of the alarm outputs see figure above. Clamp 1 Clamp 3 figure 5-3 Alarm-output contacts, alarm condition 5.6. REDUNDANCY RELAY CONFIGURATION Main Unit Substitute Unit Combining Unit AC/DC cable, 1.
User’s Manual for ION-M7P/8P S Via the redundancy relay (see illustration below), signals are switched from the Main Unit to the Substitute Unit in case an alarm raise appears in the main unit. Alarms that shall switch service to Substitute Unit in alarm condition can be selected via web interface, see description in separate software manual. ) Note: When the redundancy option is used, External Alarm IN 1, Alarm OUT 1 and Alarm OUT 2 are not available. 5.7.
6 Maintenance 6. MAINTENANCE 6.1. GENERAL Read the health and safety warnings in chapter 1.2 Health and Safety Warnings. ) Note: The remote unit does not require preventative maintenance measures. Maintenance of the ION-M7P/8P S should be performed on a FRU (Field Replaceable Unit) basis only. Do not damage the warranty labels on the components, as this voids the warranty. The spare parts list contains only units that can be replaced without tuning or soldering work.
User’s Manual for ION-M7P/8P S 6.2. OPENING AND CLOSING OF THE CABINET Before opening the cabinet of the unit, observe the instructions in chapter 4.1.1 General. To open the cabinet of the remote unit, first dismount the locker by unlocking it with the key (which is part of the delivery) and pulling it out carefully in direction of the arrow marked in figure 6-1 Locker with key. Front cover Locker figure 6-1 Locker with key If the front cover is installed (see mechanical installation in chapter 4.1.
6 Maintenance 6.3. REPLACEMENT OF POWER SUPPLY To remove the power supply, disconnect mains, mains cable and DC cable. Unscrew the five hexagon socket head cap screws (circle-marked in illustration below) with an Allen key. Pull the power supply out. Apply heat-conducting paste to the mounting surface of the new power supply. Carefully insert the new power supply. Fasten the five socket head cap screws. Re-connect all cables.
User’s Manual for ION-M7P/8P S 6.4. REPLACEMENT OF FAN UNIT The fan unit is an FRU in the ION-M7P/8P S. figure 6-4 Fan unit screws Unscrew the three M5x16 socket-head screws by which the fan unit is screwed to the cabinet. Be careful not to lose the according washers. Take off the fan unit and disconnect the connector cable from the cabinet. To install the new fan unit, proceed in reverse order.
7 Appendix 7. APPENDIX 7.1.
User’s Manual for ION-M7P/8P S figure 7-2 Layout of ION-M7P/8P S, base 7.2. SPECIFICATIONS Detailed ION-M7P/8PS product specifications are available upon request. Page 44 MF0132APA.
8 Index 8. INDEX A H Abbreviations.......................................................... 7 Address of Andrew Wireless Systems GmbH....... 13 Alarms Alarm Status .................................................... 33 Bite and Alarms ............................................... 33 External............................................................ 35 Handling of Alarms .......................................... 33 List ...................................................................