Installation Guide

M0201AJG_uc CommScope ERA
®
Medium Power Carrier Access Point Installation Guide
© Decemeber 2020 CommScope, Inc. Page 73
Replacing the Power Supply Unit (PSU)
17 Remount the CAP M. See “Mount the CAP M” on page 33.
18 Reconnect the cables to the CAP M. See “Connect the CAP M Cables” on page 57.
19 Switch on the Mains power and check the CAP M for proper operation.
The green LED starts flashing slowly as the CAP M initializes and then turns steady when initialization is
complete.
Replacing the VDC PSU
1 Switch off the circuit breaker supplying power to the CAP M.
2 Once you have confirmed that the power has been shut down, remove Mains power connector from the
unit.
3 Disconnect all remaining cables from the CAP M VAC device.
4 Unmount the CAP M device. Reverse the steps in “Mount the CAP M” on page 33.
5 Place the device on a bench or table with the connectors on the right. The PSU will be in front.