Figure 22. CAP M AC Power Cable
CAP M DC Power Cable
The standard CAP M DC power cable is a 3.2 m (10.5 ft) 13 AWG cable with a 4-pin Amphenol C016 series plug
on one end to connect to the CAP M Mains connector. The other end of the cable is unterminated with 2 end
splices to connect to the -48 Vdc power source. The standard DC power cable is shown in Figure 23.
Figure 23. CAP M DC Power Cable
Connect the CAP M Power
Connect the Power connector as appropriate for this installation:
• "Connect the Mains Power to the CAP M” on page 65
• "Connect a Hybrid Fiber Splice Box” on page 66.
Do not connect or disconnect the power cable at the Mains connector while power is on. Turn off Mains
power before connecting the power cable at the unit, then, engage mains power again.
Protecve
cap
1
2
3
4
CAP M
Mains
connector
Black
White
Green
Amphenol
4-Pin female
connector
3x
end splice
Protecve
cap
1
2
3
4
CAP M
Mains
connector
Black
Red
Amphenol
4-Pin female
connector
2x