Installation Guide

M0201AJG_uc CommScope ERA
®
Medium Power Carrier Access Point Installation Guide
© Decemeber 2020 CommScope, Inc. Page 23
Installing CAP Ms
Determine the Power Consumption of the CAP M
Use the power consumption matrix in Table 7 to calculate power consumption for a CAP M, where
the consumption numbers are at the CAP M power inputs and do not account for feed losses
the maximum consumption numbers in Table 7 do not include the power consumed by any attached
auxiliary devices. Both CAP M power consumption and auxiliary device power must be included when
calculating feed losses.
Table 7. CAP M Power Consumption
CAP M Model
Configuration
Voltage Range
(V)
Typical Power
(W)
1 2
Maximum Power
(W)
1 2
Part Number Model Name
778 1 1 25-0 0 0x CAP M 9/ 18/21/ 26
AC 90 to 264 Vac 140 150
DC -36 to -60 Vdc 140 150
782 0 4 78-0 0 0x CAP M 7E / 80 -85 /17E/ 19
AC 90 to 264 Vac 160 170
DC -36 to -60 Vdc 160 170
782 0 6 89-0 0 0x CAP M 23 / 23/ 25/ 25
AC 90 to 264 Vac 160 170
DC -36 to -60 Vdc 160 170
783 5 2 69-0 0 0x CAP M 6/ 6/7E/7E
AC 90 to 264 Vac 160 170
DC -36 to -60 Vdc 160 170
783 3 5 97-0 0 0x CAP M 8/ 18/21/ 26
AC 90 to 264 Vac 140 150
DC -36 to -60 Vdc 140 150
784 0 9 84-0 0 0x CAP M 80-85 / 17E/ 19 /26
AC 90 to 264 Vac 150 160
DC -36 to -60 Vdc 150 160
1 Does not include SFP+ Module consumption. Can support up to 3W (more with engineering consultation) maximum
total SFP+ Module consumption. Typical installation (sufficient for SM up to 10km or MM) would be 0.8W typical, 1.0W
max for each SFP+ Module.
2 Does not include power drawn by an external PoE device connected to the RJ45 Auxiliary port (Port A); in this
configuration, the CAP M will draw an additional 20W.
Mains power must be interruptible with an external delay-actions mains breaker. For the Mains breaker,
observe the following recommendations.
CAP M APs require a minimum 120 Volt / 15 Amp or 240 Volt / 13 Amp, single-phase, 50 / 60 Hz AC
service. MAINS power must be interruptible with an external delay-actions mains breaker.
CommScope recommends external AC breakers capable of at least 15 Amps maximum for 120-Volt
service or at least 13 Amps for 240-Volt service. One type B breaker can support up to two CAP M
units, and a type C breaker can support up to four CAP M units.
For the DC power supply, observe the local regulations of the DC service provider.