M0203AHA_uc CommScope ERA
®
CAP M2 with Fiber Interface
© August 2022 CommScope, Inc. Page 41
Powering on a Fiber CAP M 2
Power the CAP M2
The CAP M2 is powered on as soon as power is connected to it. Under normal operating conditions, the Power
LED turns on briefly when the unit is first detected. It will then go out briefly, followed by an initialization
period during which the Power LED flashes slowly while the CAP M2 is configured. The Power LED remains
a steady green (not flashing) once the unit reaches a fully operational state, which typically occurs within 45
seconds.
For the CAP M2 to operate, the Mains power must be connected to the CAP M2 Mains connector. Either an AC
or a DC power cable is delivered with each CAP M2—the type of power cable delivered is dependent on the
type of power supply in the CAP M2.
The Power LED behavior for a Fiber CAP M2 is as follows:
Steady Green – CAP/UAP is on and operational
Slow Flashing Green The CAP/UAP has been powered on and is initializing or if it is updating software.
Fast Flashing Green – The CAP unit identifier is active via the Flash LED function in the Era GUI.
Slow-Flashing Red – The Era GUI is reporting a critical alarm for the unit. The CAP can be recovered
without replacing hardware.
Steady Red – The Era GUI is reporting a critical alarm for the unit. The CAP or CAP component (e.g SFP+
module) must be replaced.