Installation Guide
Table Of Contents
- Table of Contents
- Document Overview
- Fiber CAP M2 Overview
- Plan and Prepare for a Fiber CAP M2 Installation
- Mount the Fiber CAP M2
- Connect the Cables to the Fiber CAP M2
- Powering on a Fiber CAP M 2
- Contacting CommScope
M0203AHA_uc CommScope ERA
®
CAP M2 with Fiber Interface
© August 2022 CommScope, Inc. Page 13
Plan and Prepare for a Fiber CAP M2 Installation
Figure 3. OCTIS Universal Lever Unmating Instructions
PLAN AND PREPARE FOR A FIBER CAP M2 INSTALLATION
Do the following before beginning installation.
1 Review and know the information in "Maximum Number of Fiber CAP M2s Supported in an ERA System”
on page 13.
2 Review and know the information in "Safely Working with ERA Hardware” on page 2.
3 "Determine the CAP M2 Installation Site” on page 14, which includes understanding and meeting
requirements for:
• "Recommended Tools and Material” on page 16
• "CAP CAP M2 Weights” on page 15
• "Recommended Tools and Material” on page 16
• "CAP M2 Dimensions” on page 15.
4 Map out all cable runs.
5 Identify and obtain all tools and materials required to complete the installation as described in
"Recommended Tools and Material” on page 16.
6 Obtain any accessories required for this installation; see "CAP M2 Accessories and Options” on page 9.
7 "Unpack and Inspect the CAP M2 and Optional Accessories” on page 16.
Maximum Number of Fiber CAP M2s Supported in an ERA System
When installing a Fiber CAP M2, you must observe the following rules.
• SMF or MMF connects the Fiber CAP M2 via its Optical Port to the OPT Card.
If the total used signal bandwidth is more than 320MHz a second fiber link is needed. It is connected to Optical
Port 2.
• You connect CAP M2s to an OPT Card installed in Slots L1, L2, L3, or L4 in the TEN or Classic CAN.
– Each OPT Card has four 10 Gbps ports (labeled 1 - 4) for fiber connections.