Installation Guide

Table Of Contents
CommScope ERA
®
CAP L2 with Fiber Interface M0203A9B_uc
Page 30 © September 2022 CommScope, Inc.
Mount the Fiber CAP L2
4 Strip the insulation of the composite cable for 100 cm and the fibers for 90 cm, and then shorten the
copper cables to 25 cm.
5 Insert the composite cable in the first cable gland and separate the
multi-fibers cable from the copper wires. It is necessary to remove the
nut to perform this action. The cable must be fed through the nut and it
must be retightened once finished.
6 Bend the spliced fibers using the corner guides and fix the splices to the
splice holder.
7 Bend the optical cables as shown in the picture to the right.
8 If a second splice holder is needed, it can be assembled using the M4
insulating washer and two M4 plain washers, as shown to the right. The
required screw is a PTK30 x 12.