Mount the Fiber CAP L2
5 Replace the junction box cover and tighten the four Phillips head screws to secure it.
6 Mount the AC/DC Power Supply Kit to the CAP L2 mounting bracket.
7 Assemble and mount the AC/DC Power Supply Kit and the CAP L2, as described below and as shown in
Figure 11 on page 27. The Local Power Jumper Cable Assembly will be connected to the AC/DC Power
Supply Junction Box at the factory.
a Use the three screws to attach the AC/DC Power Supply Unit (PSU) plate to the Wall Mounting
Bracket.
b Attach the PSU to the PSU plate.
c Attach the assembled AC/DC Power Supply Kit and Wall Mounting Bracket to the selected mounting
location.
d Mount the CAP L2 starting with Step 7 on page 23.
Figure 11. CAP L2 with AC/DC Power Supply Kit
The Power Supply/Hybrid Fiber Mounting Kit is not included with the CAP L2 and must be ordered
separately.
8 Connect the Local Power Jumper Cable (shown below) to the CAP L2 36 to 60 Vdc Power connector (see
Figure 1 on page 9).
Due to derating requirements, each CAP L2 must have its own PSU – no sharing is permitted.
Bracket, PSU Plate, PSU
Wall-mounted CAP L2 with PSU