M0203A9B_uc CommScope ERA
®
CAP L2 with Fiber Interface
© September 2022 CommScope, Inc. Page 9
Fiber CAP L2 Overview
FIBER CAP L2 OVERVIEW
This installation guide describes the Fiber CAP L2, which interfaces with a Classic CAN or TEN via an optical
link. This allows the Fiber CAP L2 to provide data over Single-Mode Fiber (SMF) or Multi-Mode Fiber (MMF).
Power for Fiber CAP L2s is provided over External AC/DC or remotely through hybrid fiber.
On the downlink, the Fiber CAP L2 converts data arriving at the CAP L2 to analog signals and sends them to
the Antenna ports. On the uplink, received signals are digitized and serialized into data streams, which are
sent back to the Classic CAN or TEN.
The Fiber CAP L2 is designed for indoor and outdoor use. It is passively cooled with a temperature range of:
-33°C to +50C (-27.4°F to +122°F); see also "Recommended Tools and Material” on page 18. The CAP L2 has a
typical power consumption that, depending on the model, ranges from 80W to 150W.
Connectors and LED for the Fiber CAP L2
Figure 1 and Table 5 identify the Fiber CAP L2 connectors and its LED; corresponding connectors are shown.
Figure 1. CAP L2 Connectors and LED (2 antennas)
Table 5. Function of the CAP L2 Connectors and LED (2 antennas)
Ref # Label Description Function
0 None Grounding Bolt Connects the CAP MX to an approved earth-ground source.
1 Port 1 Port 2 OCTIS Connector Port to pass fiber cable to the SFP+ module. The port seal is the OCTIS Universal
connector PN 7847069. Connecting the fiber cable to the CAP L2 requires removing the
service lid.
2 ANT 1 4.3-10 RF connector Connect to external antennas or to one of the ports on a multiple input cross-polarized
antenna via 50Ω coaxial cable. The antenna ports ship with dust caps that can be
discarded upon unit installation.