User's Manual Part 3

ION
®
-E Series Hardware Installation Guide M0201AA
Page 112 © June 2017 CommScope, Inc.
Installing CAP Ls
1 ConnecttheCAPLANT1and/orANT2connectortoapassiveRFantenna.
a Obtain50ΩcoaxialcablesthatareofsufficientlengthtoreachfromtheCAPLtothepassiveantenna.
Theendofthe50
ΩcoaxialcablethatwillconnecttotheANTconnectorcanbeeitherapush-pull
connectororathreadedconnector.
b Installthepassiveantennasaccordingtothemanufacturer’sinstallationinstructions.Ifconnecting
bothANTconnectors,youwillconnecttheCAP
Ltoeithertwoseparateexternalpassiveantennasor
totwoportsonacross-polarizeddualantenna.EachconnectorsupportstwoRFbands(see
Table7-9).
c Is there a dust cap on ANT 1/2 that needs to be removed?
d Connectthepassivemulti-bandantennatotheANT1orANT2connectorusingcoaxialcablewiththe
leastamountoflosspossible.
Ifthe50Ωcoaxialcablehasapush-pullconnector,makesurethecableisseatedfirmlyintheANT
1orANT2connector.
Ifthe50Ωcoaxialcablehasathreadedconnector,torquetheconnector5N-m(3.69ft-lb).Donot
over-tightentheconnector.
e Connecttheotherendofthe50ΩcoaxialcabletothepassiveantennainstalledinStepbonpage112.
2 Ifnecessary,repeatStep1onpage112toconnecta50ΩcoaxialcabletotheotherANTconnector.
3 ConnecttheOpticalPort1connectorasappropriateforthisinstallation.
a ObtainSingleModeFiber(SMF)orMultiModeFiber(MMF)thatisofsufficientlengthtoreachfrom
theCAP
LtotheION-ECAN/TEN.[when would you use SM vs. MM?]
b RemovethedustcapfromtheOpticalPort1connectorandtheconnectorsontheSMorMMfiber.
c FollowthelocalcleaningtechniquetocleanOpticalPort1.
d CleantheconnectorsontheSMForMMFfollowingthefibersupplier’srecommendations.
e ConnectoneendoftheSMForMMFtotheOpticalPort1connectorandtheotherendto[to what
EXACTLY does the other end of the cable connect on the CAN/TEN or junction box
?]
UNRESOLVED: If Opt 1 can connect to the ION-E CAN/TEN or to a local Hybrid Fiber Junction Box to provide
the main signal and power interface, when does optical transport occur over Single Mode
(SM) or Multi Mode (MM) fiber? We need to identify what type of cable to use, and does
the customer supply the cable or does it ship with the CAP
L?
Table 7-9. Mapping Frequency Bands to Antennas
Frequency Band Band Combination Antenna Port
AWS1700 / LTE2300 17E and 23 1
AWS1700 / LTE2300 17E and 23 2
GSM1800 / UMTS2100 / LTE2600 18 and 26 1
GSM1800 / UMTS2100 / LTE2600 21 and 26 2
AWS1700 / PCS1900 17E and 19 1
AWS1700 / PCS1900 17E and 19 2