Installing UAPs
Connect the UAP Cables
10 RoutetheMAINandAUX(ifneeded)Cat6Acablesthroughtherectangularopeningintheshroud(shown
below),leavingapproximately46cm(18")ofcabletoconnecttotheUAP.Whenviewingtheshroudfrom
thetop,thisopeningislabeledasMAIN.
11 Ifgroundingisrequired,insertanappropriategroundwirethroughthecircularopeningabovetheUAP
groundingscrewasshownleaving46cm(18")ofextragroundwiretoattachtothegroundingscrew.
Grounding is not mandatory. UAPs are classified as low-voltage devices and do not have internal power
supplies. However, CommScope recommends you check local and national electrical codes to determine
if grounding is a requirement for the location in which you are installing the UAP.
Insert the Cat6A cables that connect to the
UAP Main and AUX ports through the largest
rectangular opening.
If required, insert