High Power Carrier Access Point Installation Guide M0201AKG_uc
Page 40 © February 2021 CommScope, Inc.
Installing a CAP H
Clean the RF Cable Connectors
This section tells you how to clean RF cable connectors. The graphics in this section illustrate the cleaning
procedure and do not show the CAP H.
Do the following to clean the RF cable connectors.
To minimize passive inter-modulation (PIM) distortion, pay attention to the physical condition of the
connector junctions:
• Do not use connectors that show signs of corrosion on the metal surface.
• Prevent the ingress of water or dirt into the connector.
• Use protective caps for the connectors when not mounted.
• Before mounting follow the steps in "Clean the RF Cable Connectors" on page 40.
• Attach and torque the connectors properly.
• Avoid metallic abrasion when mounting the connectors by only screwing the connecting nut, but not
turning the whole connector.
• Use a torque wrench to fasten the connector, as described above.
This procedure requires the use of compressed air. Wear protective clothing—especially protective
glasses—to protect against injury from flying particles.
This procedure requires the use of flammable material. There is a risk of fire. Keep away from sources of
ignition.
This procedure requires the use of eye irritant product. There is a risk of eye irritation. Avoid contact with
eyes and skin. Wear protective clothing—especially protective glasses.
1 Gather the following cleaning tools:
• Isopropyl alcohol
• Compressed air
• Lint-free wipe
• Cotton buds.
2 Remove the protective cap from the RF connector.