CommScope Era
™
High Power Carrier Access Point Installation Guide M0201AKC
Page 44 © April 2019 CommScope, Inc.
Installing a CAP H
Connect the MAINS Power and Power on a DC CAP H
This section provides information for powering a DC CAP H. If you are installing an AC CAP H, go to
"Connect the MAINS Power and Power on an AC CAP H" on page 42
.
The MAINS cable must be properly secured observing local regulations and electrical codes. Be sure to
allow enough slack in the cable at the CAP H to mount or dismount the cable into the DC MAINS connector
of
the CAP H.
A CAP H requires M6 double-lug DC cable connectors with stud-hol
ding spacing of 15.88 mm (5/8”), as shown
in Figure 8.
M6
15.88 mm
(5/8”)
Figure 8. Required M6 Double-Lug DC Cable Connectors