Installing a CAP H
Do the following to connect the MAINS power to the CAP H.
1 F
ollow the steps in "Ground the CAP H" on page 32.
2 L
ocate the MAINS power cable that was delivered with the CAP H (shown in Figure 7 on page 42).
3 L
ocate or install a suitable power junction box or receptacle near the CAP H, and then route the power
cable from the power source to the CAP H.
Do not connect the cable to the CAP H MAINS connector at this time. The power source must be
interruptible.
4 Se
cure the MAINS cable per local regulations and electrical codes. Allow enough slack in the cable at the
CAP H to plug or unplug the cable into the CAP H MAINS connector.
5 Wire
the power cable to the junction box or receptacle. Refer to the color code and pin numbers shown in
Figure 7 on page 42.
6 W
ith the cable's MAINS plug disconnected from the CAP H, turn the circuit breaker on, unscrew the plug's
protective cover, and carefully test the plug with a voltmeter to ensure that the voltage and polarity are
correct.
7 On
cethetestinghasbeencompleted,turnoffthecircuitbreaker.
8 Unscrew the protective cover from the MAINS connecto
r of the CAP H (see Figure 7 on page 42).
9 I
nsert the plug into the MAINS connector and tighten the clamping ring until it is hand tight. Do not
over-tighten the clamping ring.
10 Turn on the c
ircuit breaker.
The CAP H is powered on as soon as power is connected to it.