Installing a CAP H
Clean the RF Cable Connectors
This section tells you how to clean RF cable connectors. The graphics in this section illustrate the cleaning
procedure and do not show the CAP H.
This procedure requires the use of compressed air. Wear protective clothing—especially protective
glasses—to protect against injury from flying particles.
This procedure requires the use of flammable material. There is a risk of fire. Keep away from sources of
ignition.
This procedure requires the use of eye irritant product. There is a risk of eye irritation. Avoid contact with
eyes and skin. Wear protective clothing—especially protective glasses.
Do the following to clean the RF cable connecto
rs.
1 Gather the following cleaning tools:
Isopropyl al
cohol
Compr
essed air
Lin
t-free wipe
Cotton buds.
2 Remove the protective cap from the RF connector.
3 Use compressed air to remove metal chips and small particles
from the mating and inner surfaces of the connector.