Installing a CAP H
2 Connect the earth-bonding cable as shown in the graphic to the right.
a L
oosen the hex nut, and then connect the earth-bonding cable between the two washers.
b Ref
asten all parts by tightening the hex nut.
c C
onnect the other end of the earth-bonding cable to a suitable permanent ground.
Flat washers
M8 Hex nut
Contact washer
Earth-Bonding cable
M8x30 set screw
M8 Hex nut
Locking ring
Ground of a second unit in a cascade must be connected to the same equipotential bonding terminal as
the Primary CAP H. Use bonding cables of the same length, as short as possible, and with a large wire cross
section. Follow local electrical code practices.