Installation Guide

Table Of Contents
CommScope Era
High Power Carrier Access Point Installation Guide M0201AKD_uc
Page 40 © December 2019 CommScope, Inc.
Installing a CAP H
2 Connect the CAP H Optical Port 1 as appropriate for this installation. Note the maximum range listed in
Table 10. See "CAP H Connectors and Status LED" on page 6 for the location of Optical Port
1.
a Remove the dust
cap from the CAP H Optical Port 1 connector and the connectors on the SMF or MMF.
b Foll
ow the local cleaning technique to clean Optical Port 1.
c C
lean the connectors on the SMF or MMF following the fiber supplier’s recommendations.
d Install the SFP+ connecto
r and Optical OCTIS Kit on the end of the SMF or MMF that will connect to
the CAP H, and then connect that end of the fiber to the CAP H Optical Port 1 connector. (Refer to the
tech
nical data sheet that ships with the OCTIS Kit for further information.)
e C
onnect the other end of the SMF or MMF to an open port on the OPT Card.
3 D
o the following only if cascading a Secondary CAP H, connect Optical Port 2 of the Primary CAP H to
Optical Port 1 of the Secondary CAP H. (Cascading of CAP H APs requires SW V2.7 or higher.)
a Rai
se the lever on the EMI/IP67 cap on Optical Port 2 connector and remove the cap.
b Remove
the caps from the connectors on the SMF or MMF.
c Foll
ow the local cleaning technique to clean Optical Port 2.
d C
lean the connectors on the SMF or MMF following the fiber supplier’s recommendations.
e Install an
SFP+ and Optical OCTIS Kit on the end of the fiber that will connect to the Primary CAP H
and connect that end of the SMF or MMF to the CAP H Optical Port 2 connector.
Note the ma
ximum range listed in Table 10. See "CAP H Connectors and Status LED" on page 6 for the
location of Optical Port 2.
Refer to the tech
nical data sheet that ships with the OCTIS Kit for further information.
f I
nstall an SFP+ and Optical OCTIS Kit on the end of the fiber that will connect to the Secondary CAP H
and connect that end of the SMF or MMF to the CAP H Optical Port 1 connector on the cascaded
Secondary CAP H.
(Optional) Connect an Auxiliary Device
Port A (Auxiliary port) provides a connection for external Ethernet devices such as WiFi and IP cameras. (The
AuxiliaryportandexternalEthernetdevicesarenotsupportedinthecurrentsoftwareversion.)
If appropriate for this installation, do the following to connect an auxiliary device.
Port A must be plugged if not in use.
1 Rai
se the lever on the EMI/IP67 cap on Port A and remove the cap (for the location of Port A, see
"CAP H Connectors and Status LED" on page 6).
2 I
nstall the Ethernet OCTIS Kit on the end of the cable that will connect to the CAP H, and then connect that
end of the cable to CAP H Port A. (Refer to the technical data
sheet that ships with the OCTIS Kit for further
information.)
This cable cannot exceed 3 meters (9.8 feet).
3 C
onnect the other end of the CAT cable to the Ethernet port of the auxiliary device.