TFAx Case B installation
CaseB remote unit can be fixed on walls, false ceilings or other flat vertical
surfaces, either directly or through a TKA04 installation kit (optional).
Installing a Case B remote unit WITHOUT the TKA kit
The TFAx kit includes:
Please consider carefully these guidelines in order to choose a proper
positioning of the remote unit and of its power supply:
o Each piece of equipment should not be affected by the heating of any other
piece. The remote unit and its external power supply should be mounted so
as to avoid reciprocal heating. Side-by-side configuration is suggested (fig.
3.22 a,b)
o Remote units are provided with cooling fins which allow to optimize heat
dissipation. In order to let them work, the environment where the TFAx is
mounted should allow the necessary air changeover
o It is strongly recommended not to mount the external power supply on a
horizontal surface, because this position does not allow heat dissipation.
External power supplies must be mounted on vertical surfaces.
o In order to assure a proper heat dissipation, the external power supplies
must be mounted in vertical position with the power socket downwards
(see fig. 13.22a,b).
Once you have chosen the position of the remote unit, please follow these
instructions:
1. In order to install the M4 screw anchors (not included) which shall hold up
the TFAx remote unit, drill into the wall according to the case B layout
shown in fig. 3.24a.
2. Fix the TFAx to the wall by firmly screwing the anchors.
3. In order to install the M4 screw anchors (not included) which shall hold up
the power supply external adapter, drill into the wall according to the
power supply layout shown in fig.3.24b
4. Fix the external power supply adapter to the wall by firmly screwing the
anchors.
5. Take the splice – tray (not included). Fix the splice holder inside the splice
tray. (see fig. 3.21a,b)
TFAx
CaseB
a. a remote unit TFAx
b. a 50 load
c. a TPSN external power supply adapter (86 to 264
Vac or -72 to -36 Vdc, according to the chosen
model)
d. a VDE connector or a -48 Vdc plug (according to
the chosen model)