User Manual

29
MN024-08
Remote units are provided with cooling fins which allow to optimize heat
dissipation. In order to let them work, the environment where the remote unit
is mounted should allow the necessary air changeover. Do not place any
remote unit face downwards on a horizontal surface, because this would
prevent heat dissipation.
Once you have chosen the position of the remote unit, please follow these
steps in order to carry out the installation:
1. Drill into the wall so as to install the M4 screw anchors (not included)
according to the case A or case B layouts indicated by the installation
drawings in fig.3.15 (a)
2. Fix the TFAx remote unit to the wall by firmly screwing the anchors.
3. Take the splice – tray (not included). Fix the splice holder inside the splice
tray. (see fig. 3.10a,b)
4. Splice the optical fibres and close the splice tray. While handling the fibers,
take care of the fiber bending.
5. Fix the splice tray beside the remote unit
6. If the remote unit is -48 Vdc powered, use the -48 Vdc plug (included) in
order to connect the unit to the -48 Vdc mains. If the remote unit is
85/264 Vac-powered, fix the 85/264 Vac plug (included) on to a power cord
(not included), and use this cable in order to connect the unit to the mains.
7. Connect the antenna RF cables to the RF antenna ports. Connect the UL and
DL optical connectors (please refer to fig. 3.4). Apply a 50-Ohm load to the
RF which are no connected to any antenna cable.
8. Once the installation is finished, please follow the section “Start-up for case
A and case B remote units”, in order to carry out a proper system start up.
Installing the Case A remote unit (except TFAM20) WITH the TKA01
installation kit
The TFAx kit includes:
The TKA01 kit includes
:
(please refer to fig.
3.11)
TFAx
CaseA
(a)
(b)
Fig. 3.10. (a) Splice tray. (b) Inside of the splice tray,
with the splice holder properly positioned.
1. a remote unit TFAx
2. a 50 load
3. a VDE connector or a -48 Vdc plug (according to
the chosen model)
A. 4 screw anchors (fixing the wall bearing to the
wall)
B. 5 screw anchors (fixing the TFAx case A to the
wall mounting box “C”)
C. A wall mounting boc
D. a splice holder