User Manual
185
MN024-08
out port of the master-side TDTX300 module. (This fiber shall be directly
connected to the optical in port of the TSRX2xx/8 module on the slave-side
subrack)
Take a SC-APC fiber, clean the fibre termination, and connect it to the optical
in port of the TMRX200 module (This fiber shall be directly connected to the
optical out port of the TDTX300 on the slave-side subrack)
Carefully insert the TSRX2xx/8 and the TDTX300 boards in 4 adjacent slots of
the Master side subrack. As already explained, take care not to have more
than 4 TFLN modules on each side of the i-link pieces. Lock the 4 screws on
the corners of each boards.
Use the provided SMA-m RF jumper in order to connect the RF Out Port of the
TSRX2xx/8 module to the RF In Port of the adjacent TDTX300 module. Use the
SMB-f jumper to connect the 10.7MHz ports of the two boards.
Use the longer RF jumpers (included) to connect each pair of TSRX UL and DL
ports to the corresponding UL and DL ports of each TFLN module mounted on
slave-side subrack. If less than 8 TFLNs are used at slave-side, make sure to
mask the TSRX-2xx/8 unused DL and UL ports by SMA loads (not provided).
Remove the protection cap from the optical ports of the 2 modules on the
slave side.
Take a SC-APC fibre, clean the fibre termination, and connect it to the optical
out port of the master-side TDTX300 module. This fiber has to be directly
connected to the optical in port of the TMRX200 module of the master-side
subrack. Use a specific torque wrench to fix the RF cables to the RF ports.
Take a SC-APC fiber, clean the fibre termination, and connect it to the optical
in port of the TSRX200 module. This fiber has to be directly connected to the
optical out port of the TDTX300 on the master-side subrack.
As you switch on the system, carefully refer to the “TILx-HL start-up” section.
TILx-
-HL
Fig. 5.33: TILx-HL slave side
DL o
p
tical cable UL o
p
tical cable