User Manual
23
6
User Manual
START
ARE ALL
REMOTE UNITS
SWITCHED ON?
YES
NO
SWITCH
THEM ON
ARE ALL
SUBRACKS SWITCHED
ON?
NO
SWITCH
THEM ON
YES
WAIT UNTIL
DISCOVERY IS FINISHED
(TFLN general alarm LED stop blinking)
CONNECT A LAPTOP
TO THE RS232
SUBRACK PORT
RUN LMT
SELECT
QUICK CONFIGURATION
MENU
MASK
SLOTS
(see LMT manual)
IS MASTER UNIT
WORKING
PROPERLY?
YES
NO
FOLLOW
TROUBLESHOOTING
PROCEDURE
ARE
REMOTE UNITS
WORKING
PROPERLY?
YES
NO
FOLLOW
TROUBLESHOOTING
PROCEDURE
IS SUPERVISION
SYSTEM INCLUDED?
YES
CONNECT THE LAPTOP
TO TSUNx LAN PORT
OPEN AN INTERNET BROWSER
AND TYPE DEFAULT ADDRESS
(see Remote Supervision manual)
LOGIN
ACCESS
CONFIGURATION MENU
AND REBOOT TO APPLY
CHANGES
NO
ACCESS
CONNECTIVITY MENU
AND RUN SYSTEM
DISCOVERY
IS SUPERVISION
SYSTEM WORKING?
YES
NO
CHECK FOR CONFIGURATION
AND RUN SYSTEM DISCOVERY
AGAIN
IS SUPERVISION
SYSTEM NOW
WORKING?
NO YES
END
HAS DISCOVERY
STARTED?
(TFLN general alarm LED blinking)
NO
YES
ENABLE IT THROUGH THE LMT OR
REMOTE SUPERVISION SYSTEM
(see relevant manuals)
MASK
TFA
(see LMT manual)
Fig. A.4: Flow-chart describing
system start-up steps