User Manual

235
MN024-08
master unit switch on and discovery up to the system configuration
through LMT Software and/or remote supervision system.
For more details on how to use LMT and about TSUNx configuration and
start-up refer to relevant manuals.
in case the system is not working properly, refer to the troubleshooting
procedures reported into relevant sections.
START
MOUNT THE SUBRACK
INTO THE CABINET
SET THE SUBRACK
BAUD RATE
(THE SAME FOR ALL)
(see Fig. 16 and Tab. 6)
SET THE SUBRACK
ADDRESS
(DIFFERENT FOR EACH)
(see Fig. 16 and Tab. 7)
IS THERE ANY
OTHER SUBRACK?
YES
NO
INSERT ALL THE
BOARDS INTO THE
SUBRACK ACCORDING
TO DESIGN
CONNECT THE BOARDS
USING RF CABLE KITS
PROVIDED
ARE ALL
BOARDS INSERTED AND
CONNECTED?
NO
YES
IS THERE A
TSUN1 OR TSUN3
DEVICE?
YES
CONNECT TSUNx COM2
PORT TO ONE
SUBRACK RS232 PORT
NO
IS THERE A
TSUN6 DEVICE?
NO
YES
CONNECT SUBRACKS
IN A DAISY CHAIN
USING RS485 PORTS
CONNECT THE
POWER CABLES
SWITCH ON THE
SUBRACK ONLY AFTER
HAVING CONNECTED
THE REMOTE UNITS
END
Fig. A.3: Flow-chart describing master unit installation and
cabling steps