User's Manual

179MN024-010
Wait until the discovery
finishes (i.e., until the
TFLN general alarm
LEDs stop blinking)
start
end
Connect a laptop to
the TSUNx LAN port)
Login to the
Supervision System
Launch the discovery
the LMT or remote
supervision system
(please see the
relevant manuals)
Connect a laptop
to the RS232
subrack port
Mask Slots (see the
LMT User ManuaI)
Select the Quick
Configuration Menu
Are all the remote
units switched ON?
Switch them
ON
Is master unit
working properly?
Are all the
subracks
switched ON?
Did the system
discovery start?
Switch them
ON
Select the Quick
Configuration Menu
Mask TFAs (see the
LMT User ManuaI)
Are the
remote units
working properly?
Does the system
includes a TSUNx
supervision unit?
Open an internet browser
and type in the default
TSUNx address
Access the Configuration
menu and reboot to
apply the changes
Is supervision
system
working properly?
Access the Configuration
menu and Run the
system discovery again
Is supervision
system
working properly?
Follow the corresponding troubleshooting
procedures (pages 111, 133-137)
Follow the corresponding troubleshooting
procedures (pages 57-63, 81-85, 93-97)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
Picture A.4:
Flow-chart describing the system start-up steps