User Manual

8 Appendix
ID No: 163511 Page 39
Output tolerance over frequency ± 1.0 dB
Output tolerance over temperature ± 1.0 dB
ICP3 optimized
4)
NF optimized
4)
Gain
5)
+33 dB
Gain @ remote unit
6)
58 dB
D
L
Output impedance 50 Ohms
ICP3 optimized
4)
NF optimized
4)
Input ICP3 +1.5 dBm -9 dBm
Noise figure (NF)
7
)
13.5 dB 6.0 dB
Gain
5)
33 dB 45 dB
Gain @ remote unit
6)
70 dB
Automatic Level Control (ALC) factory set
U
L
Input impedance 50 Ohms
1)
Mean rated output power specified for signals with 0 dB peak to average signals.
Note: The manufacturer' s rated output power of this equipment is for single carrier
operation. For situations when multiple carrier signals are present, the rating would have
to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause
interference to adjacent band users. This power reduction is to be by means of input
power or gain reduction and not by an attenuator at the output of the device.
2)
Spurious < -13 dBm @ 1 MHz RBW / -73 dBm @ 1 Hz RBW
3)
All dB and dBm figures are typical values.
4)
0 to 10 dB optical loss
5)
Gain calculation from reference point A to B, auto-levelling active (gain range software
adaptable )
6)
Auto-levelling not active
7)
Note: The noise figure (NF) stated above refers to one Remote Unit (RU) per sector. The
NF system increases with the number of the RUs per sector. It is recommended not to
operate above four RUs per sector. With four RUs per sector, the system NF will be
increased by 6 dB.
All data is subject to change without notice!
8.2.2. Environmental and Safety Specifications
) Note: For detailed information, please refer to the Environmental and
Safety Specifications leaflet of the supplier, related to ETS 300 019
(European Telecommunication Standard).
Operating temperature range -33° C to +50° C
Ingress protection IP66
All data is subject to change without notice!