Ø Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of
the fibre optic cable that will be inserted in the optical connectors on the donor
interface box.
Ø Blow out the laser receptacle with clean and dry compressed air to remove
any particulate matter.
Ø Connect the fibre optic cables by inserting the cable end into the laser
receptacle and aligning the key (on the cable end) with the keyed slot.
Ø Do not use any index matching gels or fluids of any kind in these connectors.
Gels are intended for laboratory use and attract dirt in the field.
F Note: If the unit is mounted inside a pole (see separate description) the
following procedure has to be strictly observed:
G0946MC
figure 4-10 Tight kit