User's Manual

4. Setting Up for Initial Operation
EAC-2100 Manual: (Draft, 02/01) Page 4-24
4.6 Setting Output Power
4.6.1 Setting Power Levels for Forward PAs 14
1. With the system power OFF, connect power measuring equipment to the
M1 antenna port for channels 1 and 2, and to the M2 antenna port for
channels 3 and 4. Turn the power back on. Output power may be
monitored using a through-line wattmeter (or a wattmeter with a built-in
load) to monitor output power.
2. From the SET Main Menu, type B <CR> to display the Power Amplifiers
Menu.
3. Type K <CR> to key a forward PA.
4. Type 1 <CR> to key PA 1 and display the forward power output as
measured at the sensor.
Power Amplifiers Menu
Default Values
A
Forward PA Power Step - DTC........................................................................0
B Forward PA Power Step - DCCH ....................................................................0
C Forward PA Power Step - Hand-off.................................................................0
D Forward PA Power Low Alarm Point - DTC.....................................+40 dBm
E Forward PA Power Low Alarm Point - DCCH .................................+40 dBm
F Forward PA Power Low Alarm Point - Hand-off..............................+40 dBm
G Reverse PA Power Set - DTC ............................................................+20 dBm
H Reverse PA Power Set - DCCH.........................................................+20 dBm
I Reverse PA Power Low Alarm Point - DTC .....................................+15 dBm
J Reverse PA Power Low Alarm Point - DCCH..................................+15 dBm
K Key Forward PA.................................. POWER ADJ/COMBINER TUNING
L Key Reverse PA...................................................POWER MEASUREMENT