User's Manual

4. Setting Up for Initial Operation
EAC-2100 Manual: (Draft, 02/01) Page 4-23
WARNING!! Use the minimum power step
allowable to minimize the possibility of overloading
the EAC-2100's reverse input preamplifier.
4.5.9 Programming the Modem Mobile MIN, Mobile Power Step, and
Passwords
The assigned mobile identification number (MIN) of the mobile and the
desired mobile power step should be loaded into the booster. This allows the
booster to trap calls to and from the remote link to force operation on the
donor DTC channels. By doing so, the remote link does not tie up one of the
boosted DTC channels. Passwords may also be programmed now.
1. From the System Parameters Menu, type D to display the Modem Control
Menu, shown here with default values.
2. Type K <CR> to access the Modem Mobile MIN parameter.
3. Enter the 10-digit MIN, followed by <CR>.
4. Type L <CR> to access the Modem Mobile Power Step.
5. Enter the desired power level step (7 = minimum, 0 = maximum). Enter
<CR> to record the desired power step.
6. If desired, use menu entries A and B to enter the passwords.
(They may be left at the defaults for now if desired.)
Modem Control Menu
Default Values
A
Master Password.................................................................................................1234
B Restricted Password............................................................................................5678
C Console Time-out.................................................................................30 (x 10 Sec)
D Auto-dial Enable ....................................................................................DISARMED
E Dial-up Phone Number 1 ....................................................................12163498684
F Dial-up Phone Number 2 ............................................................................... NONE
G Auto-dial Trials Max...............................................................................................10
H Delay Between Auto-dial Retries ............................................................6 (x 10 sec)
I Max Auto-dial Trial Period......................................................................9 (x 10 sec)
J Modem Setup...................................................................................PARAMETERS
K Modem Mobile MIN .............................................................................1234567890
L Modem Mobile Power Step......................................................................................7