User's Manual
4. Setting Up for Initial Operation
EAC-2100 Manual: (Draft, 02/01) Page 4-19
4.6.8 Programming Alarms and Thresholds (Continued)
4. If external analog inputs are connected to the EAC-2100 external
alarm/controls ports, type K <CR> to access the External Analog Inputs
menu.
Choose the number of the input(s) connected and program the alarm point.
You may specify DISABLED or ABOVE/BELOW a threshold, which may be
between 0 and 5 Volts.
F NOTE: If PA 7−11 Cage is not included in the unit, then the
hardware for those inputs is not installed and the alarms should be left
as DISABLED.
External Analog Inputs Menu
PA 1−6 Cage:
1 Ext. Analog Input 1 Alarm State DISABLED; Input Currently 0.0 Volts
2 Ext. Analog Input 2 Alarm State DISABLED; Input Currently 0.0 Volts
3 Ext. Analog Input 3 Alarm State DISABLED; Input Currently 0.0 Volts
4 Ext. Analog Input 4 Alarm State DISABLED; Input Currently 0.0 Volts
PA 7−11 Cage:
5 Ext. Analog Input 1 Alarm State DISABLED; Input Currently 0.0 Volts
6 Ext. Analog Input 2 Alarm State DISABLED; Input Currently 0.0 Volts
7 Ext. Analog Input 3 Alarm State DISABLED; Input Currently 0.0 Volts
8 Ext. Analog Input 4 Alarm State DISABLED; Input Currently 0.0 Volts