User's Manual

4. Setting Up for Initial Operation
EAC-2100 Manual: (Draft, 02/01) Page 4-5
4.4 Connecting a Local Terminal (Continued)
2. Power up the terminal and set it to the following parameters:
9600 baud
Even parity
7 data bits, 1 stop bit
Full duplex (no local echo)
If possible, also set the terminal to:
All capitals
Send carriage return only (no line feed)
Disable AUTO XON/XOFF and soft scroll
If you are using a terminal emulation program, select TTY or VT100. Be aware
that some terminal emulation programs generate extraneous characters that may
interfere with communicating with the EAC-2100.
3. Power up the EAC-2100. (After about 2 seconds, the terminal should respond
CONSOLE LOCKED.)
4. Enter <CR> (carriage return or enter, depending on the keyboard). (The terminal
should respond with a welcome message and prompt you for a password.)
If something comes up but is illegible, check the terminal setup.
If nothing comes up, power down. Recheck the power hookup, the terminal
hookup, and the terminal setup.
5. Enter the password, followed by <CR>. The default password is 1234. (The
terminal should respond with more salutation and the > prompt.) The system is
ready for you to set parameters.