User's Manual

3. Installing the Hardware
EAC-2100 Manual: (Draft, 02/01) Page 3-9
3.5 Connecting External Alarms/Control (Optional) (Continued)
Figure 3-7. Electrical Specifications for Inputs and Outputs
The system designer should have identified any external alarms and controls to be
connected. Make external alarm/control connections as follows:
1. Identify the input/output connection to be used for each external alarm/control that
is to be installed. Figure 3-8 shows a typical wiring diagram for external alarm
input.
2. Make connections using a compatible DB15 male connector (not supplied).
Pins Specifications
Digital Inputs (pins 6,7, 8, 9):
Load: > 100 k
Low: < 2 Vdc
High: > 4 Vdc max. +28 Vdc
Open Collector Outputs (pins 2, 3, 4, 5):
Max. +15 Vdc, 20 mA
Impedance 733
Analog input (pins
10, 11, 12, 13):
Load: 1 M
Range: 05 Vdc, 20 mV resolution
+5 Vdc source (pin 1): +5 Vdc ±5%, 100 mA max.