BRITECELL System Manual MN010-04 June 2003 Page 39 of 78
The company has a policy of continuous product development and improvement and we therefore
reserve the right to vary any information quoted without prior notice.
Slave/Remote Sub-rack Alarm status (SUB-D Female)
PIN Name Meaning Description
1 UL Summary Alarm
To choose in conjunction with PIN 2,
Normally Open
2 – 1 =Short circuit if Remote Sub
rack Uplink is in alarm
2 UL Summary Alarm Common contact
3 DL Summary Alarm
To choose in conjunction with PIN 5,
Normally Closed
5 - 3 =Open circuit if Remote Sub
rack Downlink is in alarm
4 DL Summary Alarm
To choose in conjunction with PIN 5,
Normally Open
5 – 4 =Short circuit if Remote Sub
rack Downlink is in alarm
5 DL Summary Alarm Common contact
6 UL Summary Alarm
To choose in conjunction with PIN 2,
Normally Closed
2 - 6 =Open circuit if Remote Sub
rack Uplink is in alarm
7 not connected
8 not connected
9 not connected
Tab. 7 Slave sub-rack alarm connector pinout
Normal Condition (no alarm) Alarm Condition
Down Link
Up Link
5
3
4
2
6
1
5
3
4
2
6
1